Requirements by place

ERRCS requirements where your building is

Pick your state, then your county or city. Each page shows the deadlines, signal levels and test rules your fire marshal publishes, the document behind each one, and the date we last checked it.

Updated Changelog

A fire inspector walks a corridor with a clipboard and radio.

States covered

We publish a state only when we have read its statute or fire code and at least one local fire marshal's documents.

StateLocal pagesConfidenceLast verified
Arizona1lowOct 25, 2026
California4lowOct 25, 2026
Florida17highOct 25, 2026
Texas1lowOct 25, 2026
Washington2highOct 25, 2026

Florida, county by county

Which local rules have we read?

Statewide rules (F.S. 633.202(18)) apply everywhere in Florida. A shaded county has its own page with the local fire marshal's documents. Select a county to see its pages.

Map of Florida counties with ERRCSCheck rule pages Counties with a county rules page are filled dark, counties whose own documents are not fully verified are hatched, counties with only city pages are filled light, and the rest are outlines where statewide rules apply. The table below lists every page. Alachua County Baker County Bay County Bradford County Brevard County Broward County Calhoun County Charlotte County Citrus County Clay County Collier County Columbia County DeSoto County Dixie County Duval County Escambia County Flagler County Franklin County Gadsden County Gilchrist County Glades County Gulf County Hamilton County Hardee County Hendry County Hernando County Highlands County Hillsborough County Holmes County Indian River County Jackson County Jefferson County Lafayette County Lake County Lee County Leon County Levy County Liberty County Madison County Manatee County Marion County Martin County Miami-Dade County Monroe County Nassau County Okaloosa County Okeechobee County Orange County Osceola County Palm Beach County Pasco County Pinellas County Polk County Putnam County Santa Rosa County Sarasota County Seminole County St. Johns County St. Lucie County Sumter County Suwannee County Taylor County Union County Volusia County Wakulla County Walton County Washington County
County rules on file County rules, not fully verified City rules only Statewide rules apply

County

Select a county

Tap or click a shaded county, or use Tab and Enter. Every page lists its sources and the date we last verified them.

All Florida pages in a table
JurisdictionTypeCountyConfidenceLast verified
Boca RatonCityPalm BeachlowOct 25, 2026
Broward CountyCountyBrowardmediumOct 25, 2026
Fort LauderdaleCityBrowardmediumOct 25, 2026
Hillsborough CountyCountyHillsboroughlowOct 25, 2026
HollywoodCityBrowardlowOct 25, 2026
JacksonvilleCityDuvalmediumOct 25, 2026
Miami BeachCityMiami-DadelowOct 25, 2026
Miami-Dade CountyCountyMiami-DadehighOct 25, 2026
City of MiamiCityMiami-DadelowOct 25, 2026
Orange CountyCountyOrangehighOct 25, 2026
OrlandoCityOrangehighOct 25, 2026
Palm Beach CountyCountyPalm BeachhighOct 25, 2026
Pinellas CountyCountyPinellashighOct 25, 2026
Pompano BeachCityBrowardmediumOct 25, 2026
St. PetersburgCityPinellasmediumOct 25, 2026
TampaCityHillsboroughlowOct 25, 2026
West Palm BeachCityPalm BeachlowOct 25, 2026

How these pages are built

State pages cover the statute and the state fire code. County and city pages cover what the local fire marshal publishes: signal levels, radio bands, permit steps and acceptance tests. Where a value is not published, the page says so.

Each page shows a confidence level:

  • High: we read the rule in the primary document.
  • Medium: the document is older or ambiguous.
  • Low: we could not find a primary document, and the page is a pointer to the fire marshal only.

How the rules stack up

Three layers decide what a building owes:

  1. The model code, usually Section 510 of the International Fire Code, sets a baseline (IFC 510 explained).
  2. The state either adopts that code with amendments, as Washington does, or writes its own law, as Florida does.
  3. The local fire department sets signal levels, radio bands and permit steps, and many publish their own triggers.

When the layers disagree, the local page tells you which document is newer.

Who sets the rule

Four layers decide what your building owes

  1. Layer 1The model code
    IFC Section 510, and the NFPA standard it points to (NFPA 1221, now NFPA 1225). Sets the baseline: coverage, equipment, testing.IFC 2021 510; NFPA 1225 (2022)
  2. Layer 2Your state
    States adopt the code and some write their own law. Florida's statute says who must comply, lists exemptions and set the high-rise dates.F.S. 633.202(18)
  3. Layer 3Your fire marshal (AHJ)
    Sets the signal level, the radio bands and the permit steps, and keeps a technical criteria document.F.S. 633.202(18)(a); IFC 2021 510.4.2.2
  4. Layer 4Your building
    A signal test shows whether the inside meets that level. A system is needed only where it falls short.IFC 2021 510.4.2.1; F.S. 633.202(18)(c)1
A Florida limit on local rulesLocal fire marshals may not enforce rules stricter than the Florida Fire Prevention Code and the statute on whether a system is required, or how it is designed or installed. Signal levels, bands and permit steps still differ by county.F.S. 633.202(18)(i)
Why two buildings in different cities can face different ERRCS rules: each layer narrows the one above it.Source: IFC 2021 510; F.S. 633.202(18)(a), (c)1, (i).

Local pages outside Florida

JurisdictionStateWhat the page coversConfidence
San DiegoCaliforniaNew and existing building triggers, signal levels, third-party acceptance testsmedium
Palo AltoCaliforniaSVRIA 700 MHz rules, third-party validation, 24-hour UPSmedium
San FranciscoCalifornia2025 bulletins, high-rise retrofit, system certificationhigh
Los AngelesCaliforniaLAFD Requirement #105 triggers, frequencies, Regulation No. 4 testingmedium
HoustonTexasExemption test, Texas PE plans, registered special inspectorshigh
PhoenixArizonaBenchmark RF test, permits, PE-sealed compliance certificatehigh
Pierce CountyWashingtonProof of coverage before occupancy, Class A boosters onlymedium
SeattleWashingtonNew building triggers, high-rise retrofit, 7-day annual reportsmedium

Not sure where to start? Run the checker or read Does my building need ERRCS?

Mid-rise and high-rise buildings from street level.
Outside Florida, the city or county fire marshal usually sets the details.

Next step

Take the board a plan, not just a problem

Ask for up to 3 quotes from vetted installers who serve your area, or start with a one-page brief the board can read before the next meeting. Free for owners, boards and managers. No texts, no cold calls.

Get up to 3 quotesCheck your building